Von dem Buch Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System (eBook, PDF) haben wir 2 gleiche oder sehr ähnliche Ausgaben identifiziert!

Falls Sie nur an einem bestimmten Exempar interessiert sind, können Sie aus der folgenden Liste jenes wählen, an dem Sie interessiert sind:

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System (eBook, PDF)100%: Sultana, Nadia: Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System (eBook, PDF) (ISBN: 9783960676669) 2017, Anchor Academic Publishing, Erstausgabe, in Englisch, auch als eBook.
Nur diese Ausgabe anzeigen…
Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System als von91%: Md. Iqbal Hossain, Nadia Sultana: Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System als von (ISBN: 9783960671664) Anchor Academic Publishing, in Deutsch.
Nur diese Ausgabe anzeigen…

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System (eBook, PDF)
8 Angebote vergleichen

Preise201720192023
Schnitt 39,99 43,77 39,99
Nachfrage
Bester Preis: 39,99 (vom 01.07.2017)
1
9783960676669 - Sultana, Nadia: Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System (eBook, PDF)
Sultana, Nadia

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System (eBook, PDF)

Lieferung erfolgt aus/von: Deutschland DE NW EB

ISBN: 9783960676669 bzw. 3960676662, in Deutsch, Anchor Academic Publishing, neu, E-Book.

Lieferung aus: Deutschland, Versandkostenfrei innerhalb von Deutschland.
Coronary artery disease is the most common type of heart diseases and the leading cause of death worldwide due to heart disease. It occurs when the arteries that supply blood to the heart become narrowed or blocked by a buildup of cholesterol and other material at the inner wall of the artery. Limitation of blood flow to the heart causes ischemia of the myocardial cells. Myocardial cells may die from lack of oxygen and this is called a myocardial infarction ? or more commonly: a heart attack. Coronary artery disease is the most common type of heart diseases and the leading cause of death worldwide due to heart disease. It occurs when the arteries that supply blood to the heart become narrowed or blocked by a buildup of cholesterol and other material at the inner wall of the artery. Limitation of blood flow to the heart causes ischemia of the myocardial cells. Myocardial cells may die from lack of oxygen and this is called a myocardial infarction ? or more commonly: a heart attack. Treatment options include medication, surgery or catheter-based procedures. Several types of catheter-based procedures are available. During balloon angioplasty, a special balloon catheter is passed into the narrowed segment of the artery and expands the balloon, which thus opens the artery and compresses the blockage against the wall of the artery. Stents are very small metal mesh-tubes that can be inserted via a balloon catheter into the narrowed segment of the artery. When the balloon is inflated, the stent expands and is embedded into the artery vessel wall, which thus opens the previously narrowed segment of artery. The balloon is then deflated and removed along with the catheter, and the stent is left behind to serve as a metal framework for the artery. In case of drug eluting stents a certain amount of anti-flammating drug is loaded in the coating over the base stent. This drug is released at the wall of diseased artery so that restenosis cannot take place at the place of artery where stent has been implanted. In this thesis work a drug eluting stent was studied where there was a biodegradable coating over a bare metal stent in which there was some amount of therapeutic drug. The degradation of the biodegradable coating layer thickness was determined with respect to time which was actually representing the remaining drug concentration in the coating layer. Then using this variable drug concentration as the drug concentration at initial tissue layer concentration profile of drug in tissue layer with respect to time and position was determined using finite volume algorithm, where this algorithm was coded using MATLAB programming language. Lieferzeit 1-2 Werktage.
2
9783960676669 - Md. Iqbal Hossain: Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System
Md. Iqbal Hossain

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System

Lieferung erfolgt aus/von: Deutschland ~EN NW EB DL

ISBN: 9783960676669 bzw. 3960676662, vermutlich in Englisch, Anchor Academic Publishing, neu, E-Book, elektronischer Download.

Lieferung aus: Deutschland, Versandkostenfrei.
Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System: Coronary artery disease is the most common type of heart diseases and the leading cause of death worldwide due to heart disease. It occurs when the arteries that supply blood to the heart become narrowed or blocked by a buildup of cholesterol and other material at the inner wall of the artery. Limitation of blood flow to the heart causes ischemia of the myocardial cells. Myocardial cells may die from lack of oxygen and this is called a myocardial infarction - or more commonly: a heart attack.Treatment options include medication, surgery or catheter-based procedures. Several types of catheter-based procedures are available. During balloon angioplasty, a special balloon catheter is passed into the narrowed segment of the artery and expands the balloon, which thus opens the artery and compresses the blockage against the wall of the artery. Stents are very small metal mesh-tubes that can be inserted via a balloon catheter into the narrowed segment of the artery. When the balloon is inflated, the stent expands and is embedded into the artery vessel wall, which thus opens the previously narrowed segment of artery. The balloon is then deflated and removed along with the catheter, and the stent is left behind to serve as a metal framework for the artery. In case of drug eluting stents a certain amount of anti-flammating drug is loaded in the coating over the base stent. This drug is released at the wall of diseased artery so that restenosis cannot take place at the place of artery where the stent has been implanted. In this thesis a drug eluting stent was studied where there was a biodegradable coating over a bare metal stent in which there was some amount of therapeutic drug. The degradation of the biodegradable coating layer thickness was determined with respect to time which was actually representing the remaining drug concentration in the coating layer. Then using this variable drug concentration as the drug concentration at initial tissue layer concentration profile of drug in tissue layer with respect to time and position was determined using finite volume algorithm, where this algorithm was coded using MATLAB programming language. Englisch, Ebook.
3
9783960671664 - Md. Iqbal Hossain, Nadia Sultana: Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System als von
Md. Iqbal Hossain, Nadia Sultana

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System als von

Lieferung erfolgt aus/von: Deutschland DE HC NW

ISBN: 9783960671664 bzw. 3960671660, in Deutsch, Anchor Academic Publishing, gebundenes Buch, neu.

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System: Md. Iqbal Hossain, Nadia Sultana Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System: Md. Iqbal Hossain, Nadia Sultana.
4
9783960671664 - Md. Iqbal Hossain: Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System
Md. Iqbal Hossain

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System

Lieferung erfolgt aus/von: Vereinigte Staaten von Amerika DE PB NW

ISBN: 9783960671664 bzw. 3960671660, in Deutsch, Anchor Academic Publishing, Taschenbuch, neu.

58,14 ($ 68,65)¹
unverbindlich
Lieferung aus: Vereinigte Staaten von Amerika, Lagernd, zzgl. Versandkosten.
Die Beschreibung dieses Angebotes ist von geringer Qualität oder in einer Fremdsprache. Trotzdem anzeigen
5
9783960671664 - Md. Iqbal Hossain: Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System
Md. Iqbal Hossain

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System

Lieferung erfolgt aus/von: Deutschland DE PB NW

ISBN: 9783960671664 bzw. 3960671660, in Deutsch, Anchor Academic Publishing, Taschenbuch, neu.

Lieferung aus: Deutschland, Versandkostenfrei.
Die Beschreibung dieses Angebotes ist von geringer Qualität oder in einer Fremdsprache. Trotzdem anzeigen
6
9783960671664 - Sultana, Nadia: Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System
Sultana, Nadia

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System

Lieferung erfolgt aus/von: Deutschland DE HC NW

ISBN: 9783960671664 bzw. 3960671660, in Deutsch, Anchor Academic Publishing, gebundenes Buch, neu.

Lieferung aus: Deutschland, Versandkostenfrei innerhalb von Deutschland.
Die Beschreibung dieses Angebotes ist von geringer Qualität oder in einer Fremdsprache. Trotzdem anzeigen
7
9783960671664 - Nadia Sultana: Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System
Nadia Sultana

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System

Lieferung erfolgt aus/von: Deutschland DE NW

ISBN: 9783960671664 bzw. 3960671660, in Deutsch, neu.

Lieferung aus: Deutschland, Lieferzeit: 7 Tage.
Die Beschreibung dieses Angebotes ist von geringer Qualität oder in einer Fremdsprache. Trotzdem anzeigen
8
9783960676669 - Nadia Sultana; Md. Iqbal Hossain: Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System
Nadia Sultana; Md. Iqbal Hossain

Simulation of Mass Transfer Phenomenon in a CAD Drug Eluting Stent System (2017)

Lieferung erfolgt aus/von: Deutschland ~EN NW FE EB DL

ISBN: 9783960676669 bzw. 3960676662, vermutlich in Englisch, 130 Seiten, Anchor Academic Publishing, neu, Erstausgabe, E-Book, elektronischer Download.

Lieferung aus: Deutschland, Download sofort lieferbar.
eBooks, eBook Download (PDF), Auflage.
Lade…